CONTEC MS100 SpO2 Simulator,Pulse Oximeter Accuracy Oxygen Saturation Simulation

$636.86

Category:

Description


Price: 259.43 - 636.86

If you have any question, please contact me whatsapp: +8615003353514


MANUFACTURE: CONTEC MEDICAL SYSTEMS CO.,LTD

Model Number: MS100

Brief Introduction
MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.

Features
◆ Separated connection between simulator probe and host, operation and test are more convenient.
◆ 262K color and 320*240 TFT, adjustable brightness level.
◆ Film key-press, makes the operation more comfortable.
◆ Power with chargeable lithium battery, can display the charge information of battery.
◆ Key volume, can open or close.

Main Functions
◆ Oxygen saturation simulation;
◆ Pulse rate simulation;
◆ Patient state simulation preset;
◆ Can test the reaction time of device;
◆ Can simulate the SpO2 and pulse rate under different amplitude;

◆ Can test the performance of device under different interference source; 
◆ Can select different R-curve.

Main Parameters

◆ SpO2 
Measuring range: 35%~100%
Resolution:1%
Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
◆ Pulse rate

Measuring range:25bpm~250bpm   
Resolution:5bpm
Error:1%±1bpm
◆ Amplitude

Measuring range:0.000%~20.000% 
Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
◆ Patient state
24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.

◆ Voltage  

 DC 3.6V~4.2V 
◆ Power Supply

 Voltage 3.7 rechargeable lithium battery × 1  
◆ Battery working life
Charge and discharge no less than 500 times.

Accessaries

◆ A  MS100 user manual 
◆ A  5.0V adaptor

Buy safe products:

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:

The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local 

regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to 

FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item

FDA K Number

CMS50C Pulse Oximeter
Premarket Submission Number(510K): K073454
Listing Number: D045684
CMS50D/L/DL Pulse Oximeter
Premarket Submission Number(510K): K082641
Listing Number: D064765
Sonline A/B,Baby Sound A/BPocket Fetal Doppler
Premarket Submission Number(510K): K082480
Listing Number: D072247

CMS50E,CMS50F,CMS60C,CMS60D , Pulse Oximeter
Premarket Submission Number(510K): K090671Listing Number:D078664,
,ECG80A ECG machine
Premarket Submission Number(510K): K090936
Listing Number: D081157